Menu

Low-voltage complete devices SIVACON 8PT, SIVACON S8, SIEMENS.

The company "Servismontazhintegratsiya" produces low voltage switchboards SIVACON under the license issued by SIEMENS. The devices are used for receiving, control and distribution of electricity and are used to protect power grids with voltage up to 690 V with frequency of 50 Hz.

The series equipment SIVACON is a ready functional solution for low voltage distribution units, main and auxiliary distribution panels and master control panels with degree of protection up to IP 54. Used in installations of power plants and enterprises engaged in the transport, industrial and agricultural industries, as well as on the urban infrastructure (shopping malls, schools, hospitals, etc.).

OOO "Servismontazhintegratsiya" is the official partner of the SIEMENS company. We produce low voltage switchgear SIVACON 8PT, SIVACON S8, SIVACON S4 and motor control MCC (Motor Control Center) on the basis of SIVACON.


Each unit consists of SIEMENS SIVACON standard removable or retractable modules. A variety of options and configurations of modules, easy installation and convenient replacement of the blocks allow us to implement a continuous power system and collect the equipment for any requirements and needs of the client.

info_icon

The design of the TCU suggests that under the panel Cabinet is low voltage equipment, it can be accessed through doors. Through this organization achieved a high level of safety in the use of electrical networks. Operating conditions it is quite simple: ambient temperature from -5 to +40 degrees Celsius, altitude not exceeding 2000 m above sea level, the lack of combustible gases and conductive objects nearby.

Side of the design panel

Side of the design panel

A uniform system of marking sections and feeders

A uniform system of marking sections and feeders

The positions of the main busbar up to 6300 A

The positions of the main busbar up to 6300 A

The positions of the main busbar, rear up to 7,000 A (top and/or bottom)

The positions of the main busbar, rear up to 7,000 A (top and/or bottom)

The system locks conventional or centralized

The system locks conventional or centralized

Arm door latch

Arm door latch

Download files

download-arrowКаталог SIVACON S8 (pdf, 4061 кб.)

See also

Если таблица не отображается полностью, есть возможность ее двигать проведя пальцем по экрану.

Regulatory framework

Switchgear and control equipment

Technical requirements for the design

IEC 61439-2

 

DIN EN 61439-2 (VDE 0660 part 600-2)

Checking the behavior in the presence of internal nesobrannosti (occurrence of arc)

IEC 61641, VDE 0660 part 500-2

Protection against electric shock

DIN EN 50274, VDE 0660 part 514

Rated insulation voltage (U i )

The main chainü

up to 1000 V

Nomin. operating voltage (U e )

Main circuit

up to 690 V

Air gaps and leakage paths

The calculated maximum permissible impulse voltage Uimp

8 kV

Overvoltage category

III

The level of pollution

3

erit;">the busbars

(3-pole and 4-pole)

Horizontal main busbars

Rated current

to 7000 And

Maximum allowable surge current (Ipk)

up to 330 kA

Nominal short-term permissible through current (Icw)

up to 150 kA, 1s

Vertical bus to section

with circuit breakers

Rated current

up to 6300 A

Maximum allowable surge current (Ipk)

="vertical-align: inherit;">up to 220 kA

Nominal short-term permissible through current (Icw)

up to 100 kA, 1s

Vertical bus for the partitions of the universal mounting and fixed installation

Rated current

up to 1600 A

Maximum allowable surge current (Ipk)

up to 143 kA

Nominal short-term permissible through current (Icw)

up to 65 kA *, 1s

Vertical bus for sections with 3NJ4I (fixed installation)

Rated current

up to 1600 A

Rated conditional short-circuit current (Icc)

50 kA

Vertical bus for sections with 3NJ6 (plug-in)

Rated current

up to 2100 And

The maximum allowableth surge current (Ipk)

up to 110 kA

Nominal short-term permissible through current (Icw)

to 50 kA *, 1s

The nominal current of the devices

 

Circuit breaker 3WL/3VL

to 6300 A

Cable assemblies

up to 630 A

The output feeders of the motor

to 250 kW

Internal division

IEC 61439-2, section 8.101, VDE 0660 part 600-2, 8.101

From form 1 to form 4

BS EN 61439-2

up to form 4 type 7

Surface treatment

(Coating according to DIN 43656)

Details of frame, skirting

Electro galvanised with the sendzimir method

Door

Powder coating

Sidebar

Powder coating

Rear panel, top panel

Electro galvanised with the sendzimir method

Ventilation (IPX1, IPX2)

Powder coating

Standard powder coated parts (coating Thickness 100 ± 25 µm)

RAL 7035, light grey

Details of the sections: Blue On Greenprimary

Degree of protection of IP

In accordance with IEC / EN 60529

IP30 • IP31 • IP40 • IP41 • IP42 • IP54

Dimensions

Preferred dimensions in accordance with DIN 41488

Height (without plinth):

2000 • 2200 mm

Width:

200 • 350 • 400 • 600

800 • 850 • 1000 • 1200 mm

Depth (single-row installation):

500 • 600 • 800 mm

al-align: inherit;">Depth (two-row installation):

1000 • 1200 mm

Key features of SIVACON S8

  • Higher reliability thanks to use of components, fully passed the standard tests (tested LVCD)
  • Maximum protection of staff due to security at the occurrence of the arc short circuit and also due to the protection from unauthorized access
  • High quality industrial design to fully integrate with the modern trends in the solution space
  • Efficiency thanks to the small footprint of sections from 400 x 500 mm
  • Service - unilateral, bilateral, or "back to back"
  • The height of the shield at will 2 000 mm, or 2 200 mm
  • Base / plinth 100 mm or 200 mm
  • Efficiency thanks to the use of different methods of installation in one section
  • The flexibility of placing the busbars on the top or rear, 3 - and 4-pole busbar system for currents up to 7,000 A, rated impulse withstand current lpk up to 330 kA
  • Flexible adaptation of the forms of internal separation to individual requirements, the internal division of the TCU by types 1 to 4 (DIN EN 60439-1)
  • Efficiency through the use of universal hinges, allowing you to easily change the position of the doors
  • Economical due to high efficiency ventilation system
  • The flexibility of the connection cable and tires, top, bottom and rear, cable connection from front or rear side
  • Miniature withdrawable units (½ , ¼ ) for motor and cable assemblies up to 63 A

Key features of SIVACON 8PT

  • The tested standard combination of apparatus (TTA)
  • Standardized busbar position at the top of the wardrobe
  • 3 - and 4-pole busbar system for currents up to 7400 A
  • Rated impulse withstand current Ipk up to 375 kA
  • Deep equipment compartment for universal installation
  • Modular structuresand compartment devices
  • Unilateral or bilateral service
  • Cable entry from top or bottom
  • Cable connection from front or rear side

OOO "ServisMontazhIntegratsiya"

All rights reserved, 2020